Cash Acme
|
|
|
800-876-0036
Phone: 847-356-0566 Fax: 847-356-0747 E-Mail: sales@mmcontrol.com
|
CASH ACME Backflow Prevention Devices |
Backflow prevention products protect a water supply by halting the reverse flow of water in the event of negative or decreased supply pressure. In doing so, any contaminants that may be downstream of the device cannot contaminate the water supply. Cash Acme's range of backflow prevention devices includes hose connection vacuum breakers, dual check valves, vented dual checks and atmospheric vacuum breakers. |
RPZ (bronze) Cash-Flo® Reduced Pressure Zone Backflow Preventer |
|
|
Specifications
|
Applications |
Prevention of back siphonage when connecting low and high hazard systems to potable water supply systems. |
Sizes |
1/2" (RPZ II), 3/4" (RPZ II), 3/4" 1", 1-1/4", 1-1/2" and 2" |
Approvals |
The Cash Acme RPZ is USC and ASSE 1013 listed, AWWA C511 compliant. All major national approvals. |
Benefits & Features
The Cash Acme RPZ and RPZ II prevent back siphonage. The RPZ features a short lay length and a single top access cover for easy servicing, and two distinct checks that prevent misplacement in the valve. The body, test cocks, and shut-off valves are composed of bronze.
|
RPZ (cast-iron) Cash-Flo® Reduced Pressure Zone Backflow Preventer |
|
|
Specifications
|
Applications |
Prevention of back pressure or back-siphonage into the potable water supply system when low and high hazard systems are connected. |
Sizes |
2-1/2", 3", 4", 6", 8", and 10" |
Approvals |
The Cash-Flo® RPZ is CSA and ASSE 1013 listed, AWWA C511 compliant. All major national approvals. |
Benefits & Features
The Cash-Flo® RPZ features a short lay length and a single top access cover for easy servicing. The RPZ also features two distinct checks that prevent misplacement in the valve. The body, test cocks, and shut-off valves are composed of cast-iron. |
DCV (bronze) Cash-Flo® Double Check Backflow Preventer |
|
|
Specifications
|
Applications |
Prevention of back pressure or back-siphonage into the potable water supply system when low hazard systems are connected. |
Sizes |
3/4", 1", 1-1/2" and 2" |
Approvals |
The Cash Acme DCV is USC and ASSE 1015 listed, AWWA C510 compliant. All major national approvals. |
Benefits & Features
The Cash-Flo® DCV features a top entry, single access cover and a bronze body. Four vertical test cocks and two quarter turn ball valves provide for easy and fast servicing of the valve. |
DCV (lead-free iron) Cash-Flo® Double Check Backflow Preventer |
|
|
Specifications
|
Applications |
Prevention of back pressure or back-siphonage into the potable water supply system when low hazard systems are connected. |
Sizes |
2-1/2", 3", 4", 6" and 8" |
Approvals |
The Cash-Flo® DCV is CSA and ASSE 1015 listed, AWWA C510 compliant. All major national approvals. |
Benefits & Features
The Cash-Flo® DCV features a top entry, single access cover and a ductile iron and epoxy coated body. Four vertical test cocks and two quarter turn ball valves provide for easy and fast servicing of the valve. The DCV also contains full port gate valves.
|
Cash-Flo® PVB Pressure Vacuum Breakers |
|
|
Specifications
|
Applications |
Connection of a system where a potential health hazard exists to potable water supply or irrigation system water supply. |
Sizes |
3/4", 1", 1-1/4", 1-1/2" and 2" |
Approvals |
The PVB Pressure Vacuum Breaker (Sizes 3/4" & 1") are ASSE 1020 listed. All major national approvals. |
Benefits & Features
The PVB pressure vacuum breaker is designed for installation on potable water lines to prevent contaminated water back-siphonage into the potable water supply. Assembly shall provide protection against back-siphonage where a potential health hazard exists. |
Cash-Flo® Air Gap |
|
|
Specifications
|
Applications |
Used to funnel minor relief valve discharges due to line pressure fluctuations and/or minor check valve fouling into a drainage system. |
Sizes |
1/2"- 3/4", and 3/4"- 2" (polycarbonate material), 2-1/2" through 8" (cast iron) |
Approvals |
The Cash-Flo® Air Gap is ANSI/ASME A112.1.2 standard compliant. All major national approvals. |
Benefits & Features
The Cash-Flo® Air Gap Adapter features cast iron or polycarbonate construction. Available for all backflow prevention devices. |
· Go to Top ·
|
BFSeries Dual Check Type Backflow Prevention Valves |
|
|
Specifications
|
Applications |
For continuous or intermittent applications on water supply lines. |
Sizes |
3/4", 1" and 1" swivel X 3/4" FNPT Union |
Approvals |
The BF Series is certified to ASSE 1024 and CSA B64.6. |
Benefits & Features
Prevents polluted water from entering the potable water supply system by preventing the reverse flow of water into supply lines. Cast bronze body and brass union inlet connection. The Cash Acme BF -1 is available in 3/4" and 1" sizes and incorporates a female threaded union inlet and a female threaded outlet. The Cash Acme BF -5 is available as a 1" meter threaded (swivel) inlet and 3/4" FNPT (union).
|
BFP Backflow Preventer With Intermediate Atmospheric Vent |
|
|
Specifications
|
Applications |
Boiler feed lines, dairy processing systems, livestock water sources, chlorinators, trap primers and similar installations. |
Sizes |
1/2" and 3/4" threaded or sweat. |
Approvals |
The BFP Series is certified to ASSE 1012 and CSA B.64.3. |
Benefits & Features
Prevents backflow of contaminated water into potable water supply lines. Brass body with two spring loaded poppet-type valve modules and threaded female union inlet and outlet connections. Internal strainer screen, and stainless steel springs. Suitable for hot (up to 180°F [82°C]) or cold water under continuous pressure. |
V-3 and V-3C Hose Connection Vacuum Breaker |
|
Note: These units are not intended for use where water contamination could occur as a result of draining or for permanent continuous pressure installation. For continuous pressure systems, install the BFP described here. |
Specifications
|
Applications |
For use around homes, schools, commercial buildings, laboratories, or any place involving moveable hoses attached to threaded faucets, indoors or out. |
Sizes |
3/4" |
Approvals |
The V-3 and V-3C are certified to ASSE 1011 and CSA B64.2, listed by IAPMO and approved by CSA. |
Benefits & Features
Prevents dangerous back-siphonage and backflow into a potable water supply. All-brass construction with threaded connections, neoprene seat disc, rubber washer, and steel set screw. The V-3 is equipped with a protruding "tip" device for manual draining of faucet (after hose removal) preventing freezing. Maximum pressure is 125 psi; maximum temperature is 180°F (82°C). The V-3 is available chrome-plated (V-3C) on special order. |
VB-222 Self-draining Hose Connection Vacuum Breaker |
|
Note: These units are not intended for use where water contamination could occur as a result of draining or for permanent continuous pressure installation. For continuous pressure systems, install the BFP described here. |
Specifications
|
Applications |
Designed to prevent dangerous back-siphonage and backflow into a potable water supply system. For use around homes, schools, commercial buildings, laboratories or any application involving a moveable hose attached to threaded faucets. |
Sizes |
3/4" |
Approvals |
The VB-222 is certified to ASSE 1011 and CSA 64.2 and is listed by IAPMO, ASSE, and CSA. |
Benefits & Features
Prevents dangerous back-siphonage; automatically self-drains when all attachments are removed completely from the valve's outlet. Protects the valve and faucet from freezing and rupturing in cold weather. Constructed with brass body and adapter. Buna O-ring and seat disc, steel set screw, stainless steel springs and the highest quality molded parts. |
V-101 and V-101C Atmospheric Type Vacuum Breakers |
|
|
Specifications
|
Applications |
Open tanks or basins filled by a hose below the water line; in appliances where water enters below the overflow rim; or in lawn sprinkling systems. Other applications include medical, surgical, therapeutic, and mortuary tanks. |
Sizes |
1/2", 3/4" and 1" (V-101C available in 1/2", 3/4" and 1") 1-1/4", 1-1/2" and 2" available in brass |
Approvals |
The V-101 and V-101C are certified to ASSE 1001 and CSA B64.1.1 � hose type connection, and are listed by IAPMO, ASSE, and CSA. |
Benefits & Features
Female connections, bronze body, and silicone seat. Designed for maximum intermittent water pressure of 125 psi. Suitable for temperatures up to 212°F (100°C). Not for continuous pressure use. A polished chrome model is also available (up to 1" size only). All models comply with ASSE Standard 1001, listed by IAPMO, and approved in all major cities and states.
|
VAP Automatic Plumbing Vent |
|
|
Specifications
|
Applications |
Economical solution for preventing trap siphonage and backflow of sewer gases. |
Sizes |
1-1/2" Threaded MNPT |
Approvals |
The VAP Automatic Plumbing Vent is certified to NSF-24. |
Benefits & Features
The VAP is designed to prevent backflow of sewer gases and trap siphonage at the fixture. vents by allowing air into the drain lines while the fixture is draining. An economical solution to preventing trap siphonage and backflow of dangerous sewer gases. The VAP can be securely hand tightened. |
Close Nipples |
|
|
Specifications
|
Applications |
Connection of a wide range of safety and maintenance products with female NPT threads. |
Sizes |
1/2", 3/4", 1", 1-1/4", 1-1/2" and 2" |
Benefits & Features
Cash Acme close nipples are designed to connect various products that have NPT threads. Made of brass, with short lay lengths and available in the following sizes: 1.125 (1/2"), 1.375 (3/4"), 1.5 (1"), 1.625 (1-1/4"), 1.75 (1-1/2") and 2 (2"). |
· Go to Top ·
|
|
Can't find what you are looking for? |
Call or E-mail Now
. . . for Immediate Service, Pricing, and Delivery